iio: humditiy: hdc3020: fix units for temperature and humidity measurement

According to the ABI the units after application of scale and offset are
milli degrees for temperature measurements and milli percent for relative
humidity measurements. Currently the resulting units are degree celsius for
temperature measurements and percent for relative humidity measurements.
Change scale factor to fix this issue.

Fixes: c9180b8e39 ("iio: humidity: Add driver for ti HDC302x humidity sensors")
Reported-by: Chris Lesiak <chris.lesiak@licorbio.com>
Suggested-by: Chris Lesiak <chris.lesiak@licorbio.com>
Reviewed-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Signed-off-by: Dimitri Fedrau <dimitri.fedrau@liebherr.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Dimitri Fedrau
2025-10-16 07:20:38 +02:00
committed by Jonathan Cameron
parent 3af0c1fb1c
commit 7b8dc11c0a

View File

@@ -301,9 +301,9 @@ static int hdc3020_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_SCALE:
*val2 = 65536;
if (chan->type == IIO_TEMP)
*val = 175;
*val = 175 * MILLI;
else
*val = 100;
*val = 100 * MILLI;
return IIO_VAL_FRACTIONAL;
case IIO_CHAN_INFO_OFFSET: