usb: gadget: tegra-xudc: Always reinitialize data toggle when clear halt

The driver previously skipped handling ClearFeature(ENDPOINT_HALT)
when the endpoint was already not halted. This prevented the
controller from resetting the data sequence number and reinitializing
the endpoint state.

According to USB 3.2 specification Rev. 1.1, section 9.4.5,
ClearFeature(ENDPOINT_HALT) must always reset the data sequence and
set the stream state machine to Disabled, regardless of whether the
endpoint was halted.

Remove the early return so that ClearFeature(ENDPOINT_HALT) always
resets the endpoint sequence state as required by the specification.

Fixes: 49db427232 ("usb: gadget: Add UDC driver for tegra XUSB device mode controller")
Cc: stable <stable@kernel.org>
Signed-off-by: Haotien Hsu <haotienh@nvidia.com>
Signed-off-by: Wayne Chang <waynec@nvidia.com>
Link: https://patch.msgid.link/20251127033540.2287517-1-waynec@nvidia.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Haotien Hsu
2025-11-27 11:35:40 +08:00
committed by Greg Kroah-Hartman
parent c7bbc43a17
commit 2585973c7f

View File

@@ -1558,12 +1558,6 @@ static int __tegra_xudc_ep_set_halt(struct tegra_xudc_ep *ep, bool halt)
return -ENOTSUPP;
}
if (!!(xudc_readl(xudc, EP_HALT) & BIT(ep->index)) == halt) {
dev_dbg(xudc->dev, "EP %u already %s\n", ep->index,
halt ? "halted" : "not halted");
return 0;
}
if (halt) {
ep_halt(xudc, ep->index);
} else {